Rackmount UPS System
The Ubiquiti UPS 2U Pro is a rackmount uninterruptible power supply designed to provide battery backup and surge protection for connected equipment. With a capacity of 2200 VA / 1980 W, it uses line-interactive technology and delivers a nominal output voltage of 230 V AC. The unit combines backup power and electrical protection in a 2U rackmount enclosure, making it possible to incorporate power continuity into a rack-based installation. Its eight C13 outlets and one C19 outlet provide battery backup and surge protection, allowing multiple devices to be connected to the same UPS system.
During normal operation, the UPS receives power from a 230 V AC supply through its C20 input. When operating on battery power, it produces a pure sine wave output, with a typical transfer time of 6 ms and a maximum of 10 ms. Its internal 72 V, 10 Ah lead-acid battery provides approximately 22 minutes of runtime at half load or 9 minutes at full load. These figures help determine how much backup time is available at different load levels. The battery requires approximately eight hours to recover to 90% capacity, an important consideration when planning for repeated interruptions to the incoming power supply.
Network Power Management
The UPS 2U Pro combines Ethernet-based management with a built-in 3.7-inch touchscreen, providing both network connectivity and direct interaction with the unit. Its networking interfaces include a 10/100 MbE port for management and two Gigabit Ethernet surge protection ports, identified as surge in and surge out. This arrangement separates the management connection from the Ethernet connections used for surge protection. The UPS is compatible with UniFi Network version 10.5.67 and later, integrating its management into the UniFi software environment. Physical controls include a power button, factory reset button, and circuit breaker.
The front-panel status LED communicates operating conditions through distinct colors and flashing patterns. A steady blue light indicates that the device has been adopted and is operating, while flashing blue indicates battery mode. Red indications identify warnings or low battery conditions, helping distinguish normal operation from situations requiring attention. For additional electrical protection, the UPS includes short-circuit protection through a 250 V AC, 16 A circuit breaker in online mode, as well as an emergency power-off (EPO) function. Overload protection is provided in both online and battery modes, with different shutdown thresholds and timings depending on the operating condition. Together with the touchscreen and Ethernet management, these functions give users several ways to observe device status and manage the UPS within its operating environment.
Technical Specs / Datasheet
Reviews and ratings
Product rating